Support

Why does Sasquatch return a zero or no velocity?

Last updated

September 7, 2021

Warning

Sasquatch only works with plungers that have ferrous content. Sasquatch must see the Earth’s magnetic field disrupted by the plunger.

Overview

Sasquatch works by watching a ferrous plunger go by in real time, correlating multiple key points on two separate waveforms.

Detection Issues

If the plunger is not ferrous, no waveforms are seen leading to a zero velocity being reported. While an arrival may be detected from moving parts at the well head, if the waveforms are not detectable and correlated.

Confidence Codes/Measurement Status

Along with each arrival velocity, a confidence code or measurement status is reported. This can be used to determine whether the value being reported is valid.

Based on Firmware Version 1.2.0 or later, values are:

  • -32768: Not Initialized
  • -1: Velocity Under Range
  • -2: Velocity Over Range
  • -3, -4: Velocity Calc Error
  • 2 to 8: These represent the number of points successfully correlated
  • All other numbers are invalid

Confidence codes in earlier versions of firmware were:

  • 0: Not Initialized
  • 1: Velocity Calc Error
  • 2 to 8: These represent the number of points successfully correlated
  • 20: Velocity Under Range
  • 21: Velocity Over Range
  • 22: Velocity Calc Error
  • All other numbers are invalid