Cyclops

Cyclops detects every plunger arrival using digitally filtered sensing, optimizing your well cycle after cycle. That reliability eliminates the missed arrivals and false detections that used to disrupt cycle timing and trigger unnecessary site visits.

5–24 V DC
Supply voltage
Dry contact
Normally open switch
Zone 0 / Div 1
Certified, IS model
−40 to +160°F
Operating range
Cyclops plunger arrival sensor, showing the lid and the threaded port
Explore the sensor
Select a dot to zoom in on that part.
47, 23
Geomagnetic Eye

The sensing element inside detects the shift in the earth’s magnetic field as the plunger passes.

88, 60
Sensitivity Dial

External 7-setting dial for quick tuning right at the wellhead.

24, 66
Rugged Enclosure

Sealed housing rated for -40°F to +158°F.

60, 76
1/2" NPT Port

Standard threaded connection for a clean, simple install.

74, 64
Output

Dry-contact output that connects to ALiEn2 or most other controllers.

Cyclops plunger arrival sensor

Cyclops detects a plunger's arrival in the surface equipment using Geomagnetic Sensing Technology, reading the change in the earth's magnetic field as the plunger passes, and signals any standalone controller, RTU, or PLC to advance to the next phase of the cycle. It's built for simple, plug-and-play installation and maintenance-free operation in the field.

  • Self-calibrating, advanced digital filtering eliminates missed arrivals and false detects
  • Adjustable sensitivity for reliable performance in extreme conditions
  • Rugged, user-friendly design for plug-and-play installation
  • Available in IS (Intrinsically Safe) and ExP (Explosion Proof) certified variants
  • Wide supply voltage range, 5V to 24V DC
  • Operates from -40°F to +160°F
Specification Cyclops Plunger Arrival Sensor
Supply Voltage 5 V to 24 V DC
Switch Interface Dry contact, normally open, 100 Ω impedance
Operating Temperature -40°F to +160°F (-40°C to +70°C)
Certification (IS Model) Class I, Zone 0, AEx ia IIB T4
Class I, Division 1, Groups C and D T4; Ex ia IIB T4
Class I, Zone 2, Group IIC T4
Class I, Division 2, Groups A, B, C, D T4
Certification (ExP Model) Class I, Zone 1, AEx d IIB T4
Class I, Division 1, Groups C and D; Ex d IIB T4
  • Controllers: works with ALiEn² and most other controllers, RTUs, and PLCs
  • Software: Vision Device Management via the Link adapter for real-time diagnostics and configuration
Configurations & Support
Model
Cyclops IS (Intrinsically Safe)
Cyclops ExP (Explosion Proof)
Note: Both models use the same core sensing platform, so you get the same reliable detection regardless of the configuration your site requires.
Contact Us
The Cyclops difference

Over 100,000 units sold and counting

Lines of source code on a dark screen
Self-calibrating

Self-calibrating, digitally filtered detection

Cyclops adjusts automatically to deliver dependable arrival detection, eliminating missed arrivals and false detects. Firmware is field configurable and upgradeable through Vision and Link, so new capabilities can be added without replacing hardware.

Close-up of a circuit board with a processor and gold traces
Compatibility

Works with the systems you're already running

Cyclops operates reliably across a wide range of control systems and supply voltages, from 5V to 24V DC, so it fits into the setup you already have in place.

Two engineers reviewing data on a bank of monitors
Configuration

Configured for challenging conditions

Vision Device Management unlocks additional configuration and diagnostic options, so you can test and troubleshoot even in challenging conditions like non-ferrous or stalling plungers, or excessive environmental noise.

Delivers in the field

Reliable detection in the harshest conditions

Cyclops offers adjustable sensitivity and a wide operating temperature range, delivering dependable performance even in extreme conditions. Both IS and ExP models are certified for the most demanding hazardous-area classifications, giving you a certified option for nearly any wellsite.

What you can expect

Eliminate missed arrivals, disruptions, and unnecessary site visits

Reliable detection gives your controller better information, improving cycle timing and well optimization from day one.

Up and running immediately

Plug-and-play installation means Cyclops starts delivering dependable detection right away.

More dependable cycle timing

Consistent, accurate arrival signals mean fewer disruptions and better optimization over the life of the well.

Avoid unnecessary site visits

Reliable detection means fewer trips out to investigate arrival-sensor issues or swap sensors.

Better diagnostics, right from the field

Software diagnostics identify weak arrival signals, mounting issues, or magnetic interference, giving you a clear read on the problem before you act.

Frequently asked questions

What you need to know about Cyclops.

What is Geomagnetic Sensing Technology?

Cyclops uses a magnetometer and microprocessor to read the earth's magnetic field, detecting the change created as a plunger passes rather than relying on an induced current the way older sensors do.

Will Cyclops detect a non-ferrous plunger?

Cyclops directly detects ferrous plungers. For non-ferrous plungers, the sensor can be mounted higher on the lubricator to detect movement of a ferrous spring, anvil, or trigger rod when the plunger arrives.

What's the difference between Cyclops IS and Cyclops ExP?

Both variants use the same proven sensing technology and provide the same type of arrival output. Cyclops IS is designed for intrinsically safe installations. Cyclops ExP is housed in a certified explosion-proof enclosure.

How is Cyclops powered?

Cyclops runs on 5V to 24V DC with a typical current draw of 0.77 mA, and a wireless solution is also available.

How do I see what Cyclops sees in real time?

Use the Link adapter to connect Cyclops to Vision, ETC's free device management software, to view live readings, diagnose environmental disruptions, and troubleshoot right at site in real time.

Find a Cyclops Reseller